2. Accurate Mash Temperature Control

  • Independent heating zones are provided to accommodate varying mash volumes and heat-up rates
  • Burn-on is prevented because a steam jacket can only operate when fully covered by mash
  • Soft-start steam feature allows condensate purging and prevents jacket over-stress
  • Automatic air eliminators from jackets to ensure heat transfer efficiency
  • Good mixing is essential to prevent burn-on and promote temperature homogeneity
  • Flexible heat ramp rate – 1°C or 2°F per minute is normal
  • Highly accurate temperature control – accurate to 0.2°C/0.4°F of set-point